WN: 6
Pmax (MPa): 35
Qmax (dm3/min): 60
Sandwich-plate twin throttle check valves / double throttle check valves type Z2FS
Double
Product description
- suitable for sandwich mounting in any position
- it can be used for setting override time (limiting the flow of the control stream)
- the valve can have a throttle function at both ports A and B or at only one of them
- by a certain type of mounting, one can achieve a throttle function at the supply to- or at the drain of the receiver
- setting element can be a knob or a hexagonal head screw
- the valve can be purchased in three flow versions: standard up to 60 l/min and of a reduced flow 40 or 10 l/min
Materials to download
Product variants
Sandwich-plate twin throttle check valves / double throttle check valves type Z2FS
WN: 10
Pmax (MPa): 31,5
Qmax (dm3/min): 120
Sandwich-plate twin throttle check valves / double throttle check valves type Z2FS
WN: 22
Pmax (MPa): 31,5
Qmax (dm3/min): 300
Sandwich-plate twin throttle check valves / double throttle check valves type Z2FS
WN: 16
Pmax (MPa): 35
Qmax (dm3/min): 250