The Company provides a full range of services, starting from simple cabinets controlling hydraulic power packs – to complete control systems of technological chains, equipped with PLC drivers with display and archiving of the processed data.
On Customer's request we can specially select type of control and measurement equipped, taking into consideration the existing system solutions. We also provide modernization and upgrade services to the control systems with integrated systems of supervisory control.
Hydraulic systems can also be manufactured in compliance with the requirements of quality standards AQAP and ATEX. PONAR Wadowice specialised in construction of pipelines from carbon and stainless steel, based on the Customer's or proprietary design. Our services include also flushing of pipelines to achieve the required cleanliness class. We also carry out pressure test in the assembled installation and take part in a "cold" or "hot" start-up of the hydraulic system. We design systems and equipment suitable for work with many types of working media: oils and hydraulic fluids
basic parameters of hydraulic systems | basic technical data of standard hydraulic systems |
other hydraulic systems (max. parameters subject to requirements) | ||
with a vane pump | with a gear pump | with a piston pump | ||
working pressure [max. MPa] |
16 | 30 | 35 | 63 |
pump capacity [max. dm3/min] |
60 | 100 | 300 | wg uzgodnień |
oil viscosity [mm²/s] |
10÷160 | 10÷400 | 16÷100 | max. 1000 |
rotation speed of motor [rev./min] |
1500 | 1500 | 1500 | max. 3000 |
electric motor power [max. kW] |
22 | 55 | 320 | 320 |
dokładność filtracji [µm] |
16 | 16 | 10 | subject to requirements |
tank capacity [dm3] |
4÷250 | 12÷630 | 100÷630 | subject to requirements |
optimal range of oil temp. [°C] |
40 ÷ 55 °C | 40 ÷ 55 °C | 40 ÷ 55 °C | 40 ÷ 55 °C |
allowable range of oil temp. [°C] |
20 ÷ 70 °C | 20 ÷ 70 °C | 20 ÷ 70 °C | 20 ÷ 70 °C |
ambient temp. range [°C] |
-15÷35 °C/50 °C * | -15÷35 °C/50 °C * | -15÷35 °C/50 °C * | -30÷35 °C/70 °C* |
colour | RAL 5010 | RAL 5010 | RAL 5010 | subject to requirements |
motor supply voltage | 3x400 V 50 Hz | 3x400 V 50 Hz | 3x400 V 50 Hz | subject to requirements |
control elements supply voltage | 24 V DC, 230 AC | 24 V DC, 230 AC | 24 V DC, 230 AC | subject to requirements |
* for systems with a water-oil heat exchanger